1๏ธโฃ Status Quo
โฑ
/kWh
Your blended rate = Total Bill รท Total kWh consumed.
Typical: Residential โฑ20/kWh, Commercial โฑ15/kWh.
๐ Meralco Rates
Typical: Residential โฑ20/kWh, Commercial โฑ15/kWh.
๐ Meralco Rates
โ ๏ธ Rate looks very low. Did you mean a whole number like 12 for โฑ12/kWh? Enter the full rate, not a decimal fraction.
How many weeks per year your facility operates. Businesses: typically 50 weeks (allowing for holidays). Residential: 52 weeks.
Typical: Commercial 5-6 days/week, Residential 7 days/week. This affects your total operating days per year.
kWh
Average daily electricity consumption. Check your bill for monthly kWh and divide by 30.
โฑ
Enter your actual annual bill to override the projected cost calculation.
Section 1 Results โ Your Current Electricity Costs
Operating Days/Year
0
Annual Consumption
0 kWh
Daily Consumption
0 kWh
Projected Annual Cost
โฑ0
Projected Monthly Cost
โฑ0
2๏ธโฃ PhotoVoltaic System
kW
Total solar panel capacity. Typical residential: 3-10 kW, Commercial: 50-500 kW
hrs
Peak Sun Hours (PSH) = equivalent hours of full sun (1,000 W/mยฒ) per day.
๐ต๐ญ Philippine average: 4.0โ4.5 hrs/day (conservative baseline).
Raw geographic potential: 4.5โ5.5 hrs/day.
Using 4.0 hrs accounts for clouds, monsoon rain, panel losses, and degradation.
Use the Calculate button above to estimate PSH by region, orientation, and tilt.
External data sources:
๐ Global Solar Atlas (World Bank)
๐ NREL PVWatts Calculator
๐ NREL Solar Resource Maps
๐ต๐ญ Philippine average: 4.0โ4.5 hrs/day (conservative baseline).
Raw geographic potential: 4.5โ5.5 hrs/day.
Using 4.0 hrs accounts for clouds, monsoon rain, panel losses, and degradation.
Use the Calculate button above to estimate PSH by region, orientation, and tilt.
External data sources:
๐ Global Solar Atlas (World Bank)
๐ NREL PVWatts Calculator
๐ NREL Solar Resource Maps
โฑ
/kW
Installed cost per kW including panels, inverter, labor, permits.
Benchmarks: Residential โฑ80,000/kW, Commercial โฑ50,000/kW.
Better deals = higher ROI. Get multiple quotes!
Benchmarks: Residential โฑ80,000/kW, Commercial โฑ50,000/kW.
Better deals = higher ROI. Get multiple quotes!
โฑ
Additional costs: roof waterproofing, structural reinforcement, wiring upgrades, net metering fees, engineering studies.
Section 2 Results โ PV System Output
PV Total Capacity
0 kW
Daytime PV + Battery PV
PV Equipment Cost
โฑ0
Total PV CAPEX
โฑ0
Daily Generation
0 kWh
Daily Savings
โฑ0
Annual Generation
0 kWh
3๏ธโฃ Battery Storage
โฑ
/kWh
Lithium Iron Phosphate (LFP) battery cost per kWh.
Suggested: Residential โฑ30,000/kWh, Commercial โฑ12,000/kWh.
Users can adjust based on actual quotes. LFP batteries last 10+ years.
Suggested: Residential โฑ30,000/kWh, Commercial โฑ12,000/kWh.
Users can adjust based on actual quotes. LFP batteries last 10+ years.
kWh
Size of the battery system you want to install.
Enter manually or use the reference calculation below as guidance.
Set to 0 if you don't need battery storage.
Enter manually or use the reference calculation below as guidance.
Set to 0 if you don't need battery storage.
kW
Dedicated PV capacity for charging the battery.
This is additional capacity on top of your Section 2 PV Capacity.
Formula: Battery Capacity (kWh) รท Peak Sun Hours = kW needed for full charge.
This is additional capacity on top of your Section 2 PV Capacity.
Formula: Battery Capacity (kWh) รท Peak Sun Hours = kW needed for full charge.
kWh/hr
Reference only: Average power consumption per hour during nighttime.
Used to calculate a suggested battery size below.
๐ Typical: 0.5-2 kWh/hr (aircon + fridge + fans)
๐ข Typical: 2-20 kWh/hr (security + servers + refrigeration)
Used to calculate a suggested battery size below.
๐ Typical: 0.5-2 kWh/hr (aircon + fridge + fans)
๐ข Typical: 2-20 kWh/hr (security + servers + refrigeration)
hrs
Reference only: Hours you need battery power after sunset.
Used to calculate a suggested battery size.
Typical: Residential 8 hrs (10pm-6am), Commercial 12 hrs (6pm-6am).
Used to calculate a suggested battery size.
Typical: Residential 8 hrs (10pm-6am), Commercial 12 hrs (6pm-6am).
Reference Calculation (for guidance)
Required Battery (Load ร Duration):
0 kWh
This is a suggestion. Enter your desired Battery Capacity above.
Section 3 Results โ Battery Storage
Battery Capacity
0 kWh
Battery Cost
โฑ0
PV for Battery
0 kW
Daily Charge Capacity
0 kWh
Extra PV Cost
โฑ0
Battery Charge %
0%
Daily Battery Savings
โฑ0
Annual Battery Savings
โฑ0
Monthly Battery Savings
โฑ0
No battery configured โ battery capacity is zero
4๏ธโฃ Financing
โฑ
How much of the system cost you're financing. Leave at 0 for cash purchase.
Typical: 50-100% of total system cost.
Typical: 50-100% of total system cost.
%
Bank's annual interest rate. Typical in Philippines: 8-12%.
Personal loans: 8-10%, Commercial loans: 10-12%.
Personal loans: 8-10%, Commercial loans: 10-12%.
months
Loan repayment period. Typical: 60 months (5 years).
Longer terms = lower monthly payments but more total interest.
Longer terms = lower monthly payments but more total interest.
๐ฐ Cash Purchase โ No Financing
No loan costs. Your full monthly savings go straight to recovering your investment.
โ ๏ธ Loan exceeds system cost. Your loan principal is larger than the total CAPEX. Consider reducing the loan amount to match the actual system cost.
๐ Narrative Summary Your Solar Story
๐
Ready to See Your Solar Story?
Generate a plain-language analysis of your solar investment: costs, savings, payback, and our recommendation.
Analyzing...
โ Copied to clipboard!